- CONSULTAR
Osciloscópio com largura de banda de 60MHz.
5 em 1: Osciloscópio / Gerador de sinais arbitrários / Analisador de espectro de frequência / medidor / multímetro.
Frequência de amostragem de 250MSa / s.
1M de profundidade de memória.
6000 contas DMM com gráfico de barras analógico.
Tela LCD TFT colorida de 5,6 polegadas, alta resolução (640 * 480).
| Model | DSO8060 |
| Bandwidth | 60MHz |
| Channel | 2 |
| Real-Sample Rate | 250MSa/s |
| Equivalent Sample Rate | 50GSa/s |
| Record Length | 32K |
| Rish time | ≤5.8ns |
| Timebase Accuracy | ±50ppm |
| Time Base Range | 5ns/div-1000s/div |
| Video Help | -- |
| SD Card | -- |
| Input Impandance | 1MΩ ΙΙ 15pF |
| VOLTS/DIV Range | 10mV/div~5V/div |
| A/D Converter | 8bit |
| Position Range | ±50V(5V/div), ±40V(2V/div~500mV/div), ±2V(200mV/div~50mV/div), ±400mV(20mV/div~2mV/div) |
| DC Gain Accuracy | ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div; ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div |
| Bandwidth Limit | 20MHz |
| Trigger Types | Edge, Video, Pulse, Alternative |
| Trigger Source | CH1, CH2 |
| Math | +,-,x,÷,FFT, Invert |
| Cursor Measurement | Voltage difference between cursors: △V; Time difference between cursors: △T; Reciprocal of △T in Hertz (1/ΔT); |
| Auto Measuerment | Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot |
| Waveform Frequency | DC~25MHz |
| DAC Clock | 2K~200MHz adjustable |
| Frequency Resolution | 0.10% |
| Channel count | 1CH waveform output |
| Waveform Depth | 4KSa |
| Vertical Resolution | 12 bit |
| Frequency Stability | <30ppm |
| Waveform Range | ±3.5V Max. |
| Output Impedance | 50 Ω |
| Output Current | 50mA Ipeak=50mA |
| System BW | 25M |
| Harmonic Distortion | -50dBc(1KHz), -40dBc(10KHz) |
| Frequency Range | DC~60MHz |
| Input Range | 400mVpp~18Vpp |
| Coupling Mode | DC |
| Frequency Measurement Accuracy | ±Time Base Error ±1 Count |
| Input Impedance | > 100KΩ |
| DMM Max. Resolution | 6,000 Counts |
| Testing Modes | Voltage, Current, Resistance, Capacitance, Diode & Continuity |
| Max. Input Voltage | AC: 600V, DC: 800V |
| Max. Input Current | AC:10A , DC: 10A |
| Max. Input Impandance | 10MΩ |
| Display | 5.7" TFT Display, 320*240 dots |
| Size | 245mm x 163mm x 52mm |
| Weight | 1.3KG(Without Package) |
| Standard Probe | PP80x2 |
| DMM Mode | |||
| Max. Resolution | 6000 Counts | ||
| DMM Testing Modes | Voltage, Current, Resistance, Capacitance, Diode & Continuity | ||
| Max. Input Voltage | AC:600V, DC: 800V | ||
| Max. Input Current | AC: 10A, DC:10A | ||
| Input Impedance | 10MΩ | ||
| DMM TrendPlot | 1.2M Point | ||
| Range | Resolution | Accuracy | Resolution |
| DC Voltage | 60.00mV | ±1%±3 digit | 10uV |
| 600.0mV | 100uV | ||
| 6.000V | 1mV | ||
| 60.00V | 10mV | ||
| 600.0V | 100mV | ||
| 800V | 1V | ||
| AC Voltage | 60.00mV | ±1%±3 digit | 10uV |
| 600.0mV | 100uV | ||
| 6.000V | 1mV | ||
| 60.00V | 10mV | ||
| 600.0V | 100mV | ||
| DC Current | 60.00mA | ±1%±5 digit | 10uA |
| 600.0mA | ±1.5%±5 digit | 100uA | |
| 6.000A | 1mA | ||
| 10.00A | 10mA | ||
| AC Current | 60.00mA | ±1%±5 digit | 10uA |
| 600.0mA | ±1.5%±5 digit | 100uA | |
| 6.000A | 1mA | ||
| 10.00A | 10mA | ||
| Resistance | 600 Ω | ±1%±3 digit | 0.1Ω |
| 6.000K Ω | 1Ω | ||
| 60.00K Ω | 10Ω | ||
| 600.0K Ω | 1KΩ | ||
| 6.000M Ω | 10KΩ | ||
| 60.00M Ω | ±1%±5 digit | 100KΩ | |
| Capacitance | 40.00nF | ±2%±5 digit | 10pF |
| 400.0nF | 100pF | ||
| 4.000uF | 1nF | ||
| 40.00uF | 10nF | ||
| 400.0uF | 100nF | ||
| Attention: the smallest capacitance value that can be measured in 5nF | |||
| Diode | 0V~2.0V | ||
| ON-OFF test | <10Ω |
||